EasyManua.ls Logo

Mitsubishi Electric MELSEC-Q/L - Display Instructions; Print ASCII Code

Mitsubishi Electric MELSEC-Q/L
1084 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
512
7 APPLICATION INSTRUCTIONS
7.9 Display Instructions
7.9 Display Instructions
Print ASCII code
PR
*1 Local devices and the file registers set for individual programs cannot be used.
Processing details
Outputs ASCII code stored in the device specified by (S) or ASCII code stored in the area starting from the device number
to an output module specified by (D). The number of characters output differs according to the ON/OFF status of SM701
(number of output characters selection).
(S): ASCII code or head number of the devices where the ASCII code is stored (character string)
(D): Head number of the output module to which the ASCII code will be output (bits)
Setting
data
Internal device R, ZR J\ U\G Zn Constant
$
Others
Bit Word Bit Word
(S) 
*1

(D) (Only Y) 
If SM701 is ON, characters 8 points (16 characters) from the device designated by (S) will be the target of the operation.
Basic
Redundant
Universal
LCPU
Process
High
performance
PR
D
Command
PR
S
+1
41
H
(A)
42
H
(B)
43
H
(C)
44
H
(D)
+2
45
H
(E)
46
H
(F)
47
H
(G)
48
H
(H)
+3
4B
H
(K)
4C
H
(L)
4D
H
(M)
4E
H
(N)
4F
H
(O)
50
H
(P)
49
H
(I)
4A
H
(J)
+4
+5
+6
+7
b15 b8
b7
b0
Head of output
ASCII code output
Strobe signal output
Flag indicating PR
instruction in execution
Upper 8 bits Lower 8 bits
+8
+9
+7
Sequence
program
+0
Output Y
42
H
44
H
46
H
48
H
4C
H
4E
H
50
H
4A
H
41
H
43
H
45
H
47
H
4B
H
4D
H
4F
H
49
H
S
D
S
S
S
S
S
S
S
D
D
D
Device where ASCII code is stored
Printer or
display device
Used as interlock

Table of Contents

Related product manuals