856
9 MULTIPLE CPU DEDICATED INSTRUCTIONS
9.2 Reading from the CPU Shared Memory of Another CPU
Reading from other CPU shared memory
FROM(P), DFRO(P)
When Basic model QCPU, Universal model QCPU is used
*1 Specified with the upper three digits of the four hexadecimal digits representing the start I/O number.
*2 The setting range varies depending on the auto refresh setting range of the multiple CPU high speed transmission function.
The n1 is specified by the first 3 digits of the hexadecimal 4 digits which represent the head I/O number of the slot mounted to
the CPU module.
Q00CPU, Q01CPU: The serial number (first five digits) is "04122" or later.
High Performance model QCPU: Function version B or later
n1: Start I/O number of the reading target CPU module
*1
(BIN 16 bits)
Basic model QCPU: 3E0H to 3E2H
Universal model QCPU: 3E0H to 3E3H
n2: Head address of data to be read (BIN 16 bits)
Basic model QCPU: 0 to 512
Universal model QCPU: 0 to 4095, 10000 to 24335
*2
(D): Head number of the devices where the read data is stored (BIN 16 bits)
n3: Number of read data (BIN 16 bits)
Basic model QCPU: FROM(P): 1 to 512, DFRO(P): 1 to 256
Universal model QCPU: FROM(P): 1 to 14336
*2
, DFRO(P): 1 to 7168
*2
Setting
data
Internal device R, ZR J\ U\G Zn Constant
K, H
Others
U
Bit Word Bit Word
n1 
n2 
(D) 
n3 
Slot number Head I/O number n1
CPU slot 3E00 3E0
Slot 0 3E10 3E1
Slot 1 3E20 3E2
Slot 2 3E30 3E3
Redundant
LCPU
Basic
Process
High
performance
Universal
Ver. Ver.
Command
Command
n3
n3
n1
n1
n2
n2
D
D
FROM, DFRO
FROMP, DFROP
P
indicates an instruction symbol of FROM/DFRO.