APPENDICES
Appendix 1 Operation Processing Time
1061
A
Data link
instruction
S.ZCOM When mounting CC-Link module
(master station side)
29.400 91.700 23.700 48.500 19.300 26.000
When mounting CC-Link module
(local station side)
29.500 91.600 23.700 48.500 19.100 26.200
When selecting CC-Link IE Field
Network refresh only (master
station side)
79.900 214.000 31.500 72.000 31.000 58.000
When selecting CC-Link IE Field
Network refresh only (local station
side)
79.900 214.000 31.500 72.000 31.000 58.000
When mounting MELSECNET/H
module or CC-Link IE Controller
Network module (control station
side)

When mounting MELSECNET/H
module or CC-Link IE Controller
Network module (normal station
side)

S.RTREAD 12.600 65.000 8.500 27.000 7.400 19.000
S.RTWRITE 13.300 67.100 9.000 28.000 8.300 19.800
S.REFDVWRB When the refresh device as the
write target exists at Transfer 1
90.100 98.400 98.200 118.100
When the refresh device as the
write target exists at Transfer 256
546.600 559.800 577.900 596.400
S.REFDVWRW When the refresh device as the
write target exists at Transfer 1
88.600 97.700 97.200 116.800
When the refresh device as the
write target exists at Transfer 256
544.900 554.100 588.500 606.400
S.REFDVRDB When the refresh device as the
read target exists at Transfer 1
89.500 97.900 96.000 117.300
When the refresh device as the
read target exists at Transfer 256
545.800 559.000 577.000 595.500
S.REFDVRDW When the refresh device as the
read target exists at Transfer 1
88.500 97.700 95.800 116.800
When the refresh device as the
read target exists at Transfer 256
545.100 554.000 589.600 606.100
Communication
protocol
function
instruction
S(P).CPRTCL 138.000 192.600 68.600 83.100 50.700 60.300
S.TO n1 n2 n3
n4 (D)
Writing to host CPU
shared memory
n4=1 
n4=320 
TO n1 n2 (S)
n3
Writing to host CPU
shared memory
n3=1 
n3=320 
DTO n1 n2 (S)
n3
Writing to host CPU
shared memory
n3=1 
n3=320 
FROM n1 n2
(D) n3
Reading from host
CPU shared memory
n3=1 
n3=320 
Reading from other
C
P
U shared memory
n3=1 
n3=320 
n3=1000 
DFRO n1 n2
(D) n3
Reading from host
CPU shared memory
n3=1 
n3=320 
Reading from other
CPU shared memory
n3=1 
n3=320 
n3=1000 
Category Instruction Condition (device) Processing time (s)
L02SCPU, L02SCPU-
P
L02CPU, L02CPU-P L06CPU, L06CPU-P,
L26CPU, L26CPU-P,
L26CPU-BT, L26CPU-
PBT
Min. Max. Min. Max. Min. Max.