6 BASIC INSTRUCTIONS
6.2 Arithmetic Operation Instructions
223
6
Operation error
There is no operation error in the +(P) or -(P) instruction.
Program example
The following program adds, when X5 is turned ON, the data at D3 and D0 and outputs the operation result at Y38 to Y3F.
The following program outputs the difference between the set value for timer T3 and its present value in BCD to Y40 to
Y53.
[Ladder Mode] [List Mode]
[Ladder Mode] [List Mode]
Step
Instruction
Device
Step
Instruction
Device

Table of Contents