300
6 BASIC INSTRUCTIONS
6.4 Data Transfer Instructions
Program example
The following program stores the real numbers at D10 and D11 at D0 and D1.
The following program stores the real number -1.23 at D10 and D11 when X8 is ON.
[Ladder Mode] [List Mode]
[Operation]
[Ladder Mode] [List Mode]
[Operation]
Step
Instruction
Device
D11
36.475
D10
D1
36.475
D0
Step
Instruction
Device
D11 D10
1.23
1.23