7 APPLICATION INSTRUCTIONS
7.1 Logical Operation Instructions
365
7
WOR(P), DOR(P) [When three data are set]
Processing details
WOR
Conducts a logical sum operation on each bit of the 16-bit data of the device designated by (S1) and the 16-bit data of the
device designated by (S2), and stores the results at the device designated by (D).
For bit devices, the bit devices after the points designated by digit specification are regarded as "0" in the operation.
DOR
Conducts a logical sum operation on each bit of the 32-bit data of the device designated by (S1) and the 32-bit data of the
device designated by (S2), and stores the results at the device designated by (D).
For bit devices, the bit devices after the points designated by digit specification are regarded as "0" in the operation.
(S1), (S2): Data for a logical sum operation or head number of the devices where the data is stored (BIN 16/32 bits)
(D): Head number of the devices where the logical sum operation result will be stored (BIN 16/32 bits)
Setting
data
Internal device R, ZR J\ U\G Zn Constant
K, H
Others
Bit Word Bit Word
(S1) 
(S2) 
(D) 
Command
Command
P
WOR, DOR
WORP, DORP
S1
S2
S1
S2
D
D
indicates an instruction symbol of WOR/DOR.
0000
11
00
11
0000
11
1100110011110011
b15 b8 b0b7
b0b7b15 b8
OR
11
000000
1111
0000
b0b7b15 b8
S1
S2
D
00
1
0
11
0000
1111
b0
b15
b31
b16
OR
00
11
00
11
00
11
00
b0
b15
b31
b16
0011 111100 1111
b31
b16
b0
b15
+ 1
+ 1
+ 1
S1
S2
S1 S1
S2
S2
D
D D