EasyManua.ls Logo

Mitsubishi Electric MELSEC-Q/L - Page 402

Mitsubishi Electric MELSEC-Q/L
1084 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
400
7 APPLICATION INSTRUCTIONS
7.3 Shift Instructions
Operation error
In any of the following cases, an operation error occurs, the error flag (SM0) turns ON, and an error code is stored into SD0.
Program example
The following program shifts the contents of D683 to D689 to the right when XB is turned ON.
The following program shifts the contents of D683 to D689 to the left when XB is turned ON.
Error
code
Error details Q00J/
Q00/
Q01
QnH QnPH QnPRH QnU LCPU
4101 The points specified in n exceed those of the corresponding device specified
in (D).

[Ladder Mode] [List Mode]
[Operation]
[Ladder Mode] [List Mode]
[Operation]
Step Instruction Device
D686
D686D689 D688 D687 D685 D684 D683
D689 D688 D687 D685 D684 D683
503 600 3802
5003
0 503 600 3802
Filled with 0.
Designation range for the DSFRP instruction
-32765-336-100
-100 -336
-32765
Step Instruction Device
D686
D686D689 D688 D687 D685 D684 D683
D689 D688 D687 D685 D684 D683
-100 503 600 -336 3802 -32765 5003
503 600 -336 3802 -32765 5003 0
Filled with 0.
Designation range for the DSFLP instruction

Table of Contents

Related product manuals