7 APPLICATION INSTRUCTIONS
7.5 Data Processing Instructions
451
7
Operation error
In any of the following cases, an operation error occurs, the error flag (SM0) turns ON, and an error code is stored into SD0.
Program example
The following program stores the average value of 16-bit data stored from D0 to D2 into D10, when M0 is turned on.
The following program stores the average value of 32-bit data stored from D0 to D5 into D10 and D11, when M0 is turned
on.
Error
code
Error details Q00J/
Q00/
Q01
QnH QnPH QnPRH QnU LCPU
4100 The value specified in n is other than 0 to 32767. 
4101 The points specified in n exceed those of the corresponding device specified
in (S).

[Ladder Mode] [List Mode]
[Operation]
[Ladder Mode] [List Mode]
[Operation]
Step
Instruction
Device
(BIN)
(BIN)
(BIN)
D1
D10
D0
D2
550
(BIN)
105
555
990
Step
Instruction
Device
(BIN)
(BIN)
(BIN)
D11,D10
D1,D0
D3,D2
D5,D4
2101176
(BIN)
623541
4753647
926342