7 APPLICATION INSTRUCTIONS
7.12 Special Function Instructions
605
7
Program example
The following program performs a TAN operation on the angle data set by the 4 BCD digits from X20 to X2F, and stores the
results as 64-bit floating decimal point type real numbers at D0 to D3.
[Ladder Mode]
[List Mode]
[Operations involved when X20 to X2F designate a value of 135]
Inputs an angle used for TAN
operation ( ).
Converts the input angle into a
64-bit floating-point real number ( ).
Converts the converted angle into a
radian value ( ).
Executes TAN operation using the
converted radian value ( ).
1
2
3
4
Step Instruction Device
64-bit floating-point
real number
X2F
BCD value
0
D30
135
X20
Conversion
to BIN
BIN
b15
b0
BIN value
Conversion to radian
RADD
TAN operation
TAND
135
Conversion to
floating-point
FLTD
D21
135
D20D23 D22
64-bit floating-point
real number
D21
2.356194
D20D23 D22
64-bit floating-point
real number
D21
-1.000000
D20D23 D22
1
2
3
4

Table of Contents