7 APPLICATION INSTRUCTIONS
7.12 Special Function Instructions
645
7
Program example
This following program obtains the value for common logarithm of the 64-bit floating-point data type real number specified
by D600 to D603 when M0 is turned on. Then the program stores the operation result into D123 to D126.
[Ladder Mode] [List Mode]
[Operation]
Step
Instruction
Device
Log
10
D126 D125 D124 D123D603 D602 D601 D600
0.4480882.806

Table of Contents