676
7 APPLICATION INSTRUCTIONS
7.13 Data Control Instructions
Operation error
In any of the following cases, an operation error occurs, the error flag (SM0) turns ON, and an error code is stored into SD0.
Program example
The following program executes scaling for the scaling conversion data of which the devices specified at D110 and up are
set with the input value specified at D0, and then outputs the data at D200.
Error
code
Error details Q00J/
Q00/
Q01
QnH QnPH QnPRH QnU LCPU
4100 The X coordinates are not set in ascending order.
The input value specified in (S1) is not within the range of the scaling
conversion data set.
The number of X and Y coordinates of the device specified in (S2) is not
within the range from 1 to 32767.

4101 The number of X and Y coordinates of the device specified in (S2) exceeds
the specified range.

[Ladder Mode] [List Mode]
[Operation]
Step
Instruction
Device
D110 K5
D111 K7
D112 K13
D113 K15
D114 K18
D115 K20
D116 K-14
D117 K-7
D118 K-15
D119 K-11
D120 K-18
Y
X
(18, -11)
(20, -13)
(15, -9)
(13, -7)
(7, -14)
D0=11
Scaling conversion data component
Setting item Device Setting contents
Number of coordinate points
X coordinate
Y coordinate
Point 1
Point 2
Point 3
Point 2
Point 4
Point 5
Point 1
Point 3
Point 4
Point 5
D200=-9
Point 1
Point 2
Point 3
Point 5
Point 4
(Output value)
(Input value)