EasyManua.ls Logo

Mitsubishi Electric MELSEC-Q/L - Page 776

Mitsubishi Electric MELSEC-Q/L
1084 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
774
7 APPLICATION INSTRUCTIONS
7.19 Other Instructions
On the LCPU, if the built-in I/O or first I/O on the built-in CC-Link is specified, then the model name of the CPU
module is read.
LCPU (L26CPU-BT)
When the target module occupies two slots
The start I/O number to be specified may differ from that of the mounted module.
For the start I/O number, refer to the manual of each module.
The value of n is specified by the first 3 digits of the hexadecimal 4 digits that represent the start I/O number of a module whose model name is to be read.
QJ71GP21S-SX Specify a value that is the sum of the start I/O number of the mounted module and 0010H.
When the target module is
a CPU module in multiple
CPU systems
Specify the first 3 digits of the hexadecimal 4 digits which represent the start I/O number of each CPU module.
Or, the model name can be read by specifying the start I/O number of a module controlled by another CPU.
When the target module occupies one slot
Power
supply
module
CPU
Built-in
I/0
Built-in
CC-Link
LX40
C6
LX40
C6
LX40
C6
L60A
D4
LY41
NT1P
LY10
R2
LY10
R2
LY10
R2
0000
H 0010H 0030H 0040H 0050H 0060H 0070H 0090H 00A0H 00B0H
Specify H3E0 to read the module name of the CPU module.
Specify K6 or H6 as the start I/O number to be read.
Start I/O number
configured in the I/O
assignment setting
CPU module
(L26CPU-BT)
Power
supply
module
CPU
module
QJ71G P21S-SX
Empty Empty Empty Empty Empty Empty
3E00
H 0000H 0010H 0030H 0040H 0050H 0060H 0070H 0080H
Start I/O number configured in
the I/O assignment setting
Specify K1 or H1 as the start I/O number to be read.
Power
supply
module
CPU
module
Q20UDH
CPU
Q20UDH
CPU
Q20UDH
CPU
QY41
P
Q68
ADV
QY41
P
QY10 QY10
3E00
H 3E10H 3E20H 3E30H 0000H 0020H 0030H 0050H 0060H
Start I/O number configured in
the I/O assignment setting
Specify 3E3H as the start I/O number to be read.

Table of Contents

Related product manuals