EasyManua.ls Logo

Mitsubishi Electric MELSEC-Q/L - Page 792

Mitsubishi Electric MELSEC-Q/L
1084 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
790
7 APPLICATION INSTRUCTIONS
7.19 Other Instructions
*2 Indicates the range applicable for the Universal model QCPU, LCPU.
(D0) (D0)+4
(D0)+5
File position Designate the file position to start reading when binary
data reading is designated by (D0).
00000000H: Starting at the beginning of the file
00000001H to FFFFFFFEH: From the designated
position (The unit for the value is determined by word/
byte unit designation.)
FFFFFFFFH: Setting disabled
When CSV format read is specified at (D0)
For the High Performance model QCPU of which
the first five digits of the serial number are "01111"
or lower, always set the beginning (0H) of the file.
For the High Performance model QCPU/Process
CPU/Redundant CPU/Universal model QCPU/
LCPU of which the first five digits of the serial
number are "01112" or higher, set the file position
(Row).
00000000H: Read starts at the beginning of the file.
00000001H to FFFFFFFEH: Read starts at the
specified row.
FFFFFFFFH: Read continues, starting at the previous
read position.
00000000H to
FFFFFFFFH
User BIN 16 bits
(D0)+6 No. of columns
designation
When binary read is specified at (D0), always set 0.
When read data after CSV format conversion is
specified at (D0), set the number of columns from
where data will be read.
0: No columns. Regarded as one row.
Other than 0: Regarded as the specified number of
columns.
0H to FFFFH (0
to 65535)
User
(D0)+7 Data type
specification
0: Word
1: Byte
0, 1 User
(S1) Head number of the devices storing a file name. A file name is expressed as follows: BIN 16 bits
Device Item Contents/setting data Setting range Set by
(S1) to
(S1)+
File name
character string
Designate the character string of a file name.
When omitting an extension, also omit the "."
(Period).
Limit the file name within 8 characters + period + 3
characters.
When 9 or more characters are used, the extension
is ignored regardless of its presence, and "BIN" or
"CSV" is regarded as an extension.
Character string User
(D1) Head number of the devices for storing the read data. BIN 16 bits
Device Item Contents/setting data Setting range Set by
(D1) Reading result
(No. of read
data)
Contains the number of actually read data against the
data designated by (D0)+2. The unit on the value
depends on data type specification.
System
(D1)+1 to
(D1)+
Reading data Read data System
(D2) Bit device that turned ON at the completion of the processing. ((D2)+1 is also turned ON at error completion.) Bit
Device Item Contents/setting data Setting range Set by
(D2) Completion
signal
Indicates the completion of the processing.
ON: Completed
OFF: Not completed
System
(D2)+1 Error
completion
signal
Indicates whether the processing is normally
completed or abnormally completed.
ON: Error completion
OFF: Normal completion
Setting
data
Meaning Setting range Set by Data type

Table of Contents

Related product manuals