818
7 APPLICATION INSTRUCTIONS
7.19 Other Instructions
Operation error
In any of the following cases, an operation error occurs, the error flag (SM0) turns ON, and an error code is stored into SD0.
Program example
This program displays the string stored after D10 on the display unit, when X10 is set to "on".
Error
code
Error details Q00J/
Q00/
Q01
QnH QnPH QnPRH QnU LCPU
4100 More than 128 characters are specified in the (S) string. 
4101 There is no NULL code (00H) within the range of the target device following
the device number specified by (S)

[Ladder Mode] [List Mode]
[Operation]
Step Instruction Device
4C
H
(i)
6E
H
(e)
2D
H
(A)
20
H
(w)
6F
H
(r)
6B
H
(i)
6E
H
(g)
b15 to b8
69
H
(L)
65
H
(n)
41
H
(-)
77
H
( )
72
H
(o)
69
H
(k)
67
H
(n)
00
H
D10
D11
D12
D13
D14
D15
D16
D17
Run UMSG
instruction
b7 to b0
Line-A Working
User message