8 INSTRUCTIONS FOR DATA LINK
8.3 Refresh Device Write/Read Instructions
837
8
Precautions
Do not execute the instruction in an interrupt program. If the instruction is executed, no processing is performed. In
addition, the completion device ((D1)+0), the completion device ((D1)+1), and SM739 do not turn on. If the instruction is
executed in a fixed scan execution type program, they also do not turn on.
When the instruction is executed, do not rewrite the device data in (S2) until the completion device turns on.
Specifying digit for the bit device can be used only when the following conditions are met.
When the above conditions are not met, INSTRCT CODE ERR. (error code: 4004) will occur.
Digit specification: K4
Head of device: multiple of 16