8 INSTRUCTIONS FOR DATA LINK
8.3 Refresh Device Write/Read Instructions
839
8
Number of points specified in n2 is read from the device specified in (D1) to the offset specified in (S1)+2 of the refresh
device assigned for the device specified in (S1)+1 of the target station specified in n1 and (S1)+0.
At the above configuration, number of points specified in n2 is read starting from the offset (X1078) specified in (S1)+2 of
the device assigned for the station number 4, then the number of points is read to devices starting from the device specified
in (D1).
When a refresh range per station is assigned in transfer settings, specify number of read points so that the
range read data from the specified offset is within the range assigned in the same transfer setting. An error
occurs if the number of read points over the range assigned in each transfer setting is specified.
Refresh device
X1000
CPU module
CPU
module
Master
station:
Station
No. 0
Specified
station:
Station
No. 4
Station
No. 1
Remote input (RX)
CC-Link master station:
Station No. 0
Start I/O No.: 0000
H
Start I/O No.: n1=0
Remote input (RX)
Remote input (RX)
Remote device station:
Station No. 1
Remote device station:
Station No. 4
.....
.....
Type: +1=1S1
Station number:
+0=4
S1
Refresh device areas assigned for station No. 4
X100F to X1000
X101F to X1010
X102F to X1020
X103F to X1030
X104F to X1040
X105F to X1050
X106F to X1060
X107F to X1070
X108F to X1080
X109F to X1090
X10AF to X10A0
X10BF to X10B0
RX0F to RX00
RX1F to RX10
RX0F to RX00
RX1F to RX10
RX0F to RX00
RX1F to RX10
RX2F to RX20
RX3F to RX30
RX4F to RX40
RX5F to RX50
RX6F to RX60
RX7F to RX70
RX8F to RX80
RX9F to RX90
RXAF to RXA0
RXBF to RXB0
[Structure]
Start number of the device
where target data is stored:
Number of
read points:
n2=4
Offset reference point
(start point: 0)
X1078 is the 24th bit from the offset reference
point. Specify the offset in hexadecimal, 18
H.
Refresh device areas
assigned for the remote
output (RX) of station No. 4
=M1240D1
+2=18HS1
X1060
X1070
M1240
9
FEDCBA9876543210
FEDCBA9876543210
876543210