900
APPENDICES
Appendix 1 Operation Processing Time
Basic instructions
The processing time when the instruction is not executed is calculated as follows:
Q02CPU: 0.079 (No. of steps for each instruction + 1) s
Q02HCPU, Q06HCPU, Q12HCPU, Q25HCPU, Q02PHCPU, Q06PHCPU, Q12PHCPU, Q25PHCPU, Q12PRHCPU,
Q25PRHCPU: 0.034 (No. of steps for each instruction + 1) s
Instruction Condition (device) Processing time (s)
Qn QnH QnPH QnPRH
LD= In conductive status 0.24 0.10 0.10 0.10
In non-conductive status 0.24 0.10 0.10 0.10
AND= When not executed 0.24 0.10 0.10 0.10
When executed In conductive
status
0.24 0.10 0.10 0.10
In non-conductive
status
0.24 0.10 0.10 0.10
OR= When not executed 0.24 0.10 0.10 0.10
When executed In conductive
status
0.24 0.10 0.10 0.10
In non-conductive
status
0.24 0.10 0.10 0.10
LD<> In conductive status 0.24 0.10 0.10 0.10
In non-conductive status 0.24 0.10 0.10 0.10
AND<> When not executed 0.24 0.10 0.10 0.10
When executed In conductive
status
0.24 0.10 0.10 0.10
In non-conductive
status
0.24 0.10 0.10 0.10
OR<> When not executed 0.24 0.10 0.10 0.10
When executed In conductive
status
0.24 0.10 0.10 0.10
In non-conductive
status
0.24 0.10 0.10 0.10
LD> In conductive status 0.24 0.10 0.10 0.10
In non-conductive status 0.24 0.10 0.10 0.10
AND> When not executed 0.24 0.10 0.10 0.10
When executed In conductive
status
0.24 0.10 0.10 0.10
In non-conductive
status
0.24 0.10 0.10 0.10
OR> When not executed 0.24 0.10 0.10 0.10
When executed In conductive
status
0.24 0.10 0.10 0.10
In non-conductive
status
0.24 0.10 0.10 0.10
LD<= In conductive status 0.24 0.10 0.10 0.10
In non-conductive status 0.24 0.10 0.10 0.10
AND<= When not executed 0.24 0.10 0.10 0.10
When executed In conductive
status
0.24 0.10 0.10 0.10
In non-conductive
status
0.24 0.10 0.10 0.10
OR<= When not executed 0.24 0.10 0.10 0.10
When executed In conductive
status
0.24 0.10 0.10 0.10
In non-conductive
status
0.24 0.10 0.10 0.10
LD< In conductive status 0.24 0.10 0.10 0.10
In non-conductive status 0.24 0.10 0.10 0.10

Table of Contents