EasyManua.ls Logo

Mitsubishi Electric MELSEC-Q/L - Page 955

Mitsubishi Electric MELSEC-Q/L
1084 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
APPENDICES
Appendix 1 Operation Processing Time
953
A
Basic
instruction
AND$<= When not executed 0.360 0.240 0.180 0.120
When executed In conductive
status
7.100 36.500 7.100 36.500 7.100 36.500 6.000 16.000
In non-
conductive
status
7.100 36.500 7.100 36.500 7.100 36.500 6.100 16.200
OR$<= When not executed 0.360 0.240 0.180 0.120
When executed In conductive
status
7.400 35.600 7.400 35.600 7.400 35.600 4.700 14.600
In non-
conductive
status
7.400 35.600 7.400 35.600 7.400 35.600 4.600 14.400
LD$< In conductive status 7.400 40.000 7.400 40.000 7.400 40.000 4.800 17.000
In non-conductive status 7.400 40.000 7.400 40.000 7.400 40.000 5.500 18.000
AND$< When not executed 0.360 0.240 0.180 0.120
When executed In conductive
status
8.000 37.300 8.000 37.300 8.000 37.300 5.900 13.400
In non-
conductive
status
8.000 37.300 8.000 37.300 8.000 37.300 6.200 14.500
OR$< When not executed 0.360 0.240 0.180 0.120
When executed In conductive
status
8.300 35.600 8.300 35.600 8.300 35.600 6.200 18.700
In non-
conductive
status
8.300 35.600 8.300 35.600 8.300 35.600 5.400 19.700
LD$>= In conductive status 7.400 38.300 7.400 38.300 7.400 38.300 4.800 10.000
In non-conductive status 7.400 38.300 7.400 38.300 7.400 38.300 5.500 11.200
AND$>= When not executed 0.360 0.240 0.180 0.120
When executed In conductive
status
7.200 37.300 7.200 37.300 7.200 37.300 4.400 21.600
In non-
conductive
status
7.200 37.300 7.200 37.300 7.200 37.300 4.500 21.800
OR$>= When not executed 0.360 0.240 0.180 0.120
When executed In conductive
status
8.200 36.400 8.200 36.400 8.200 36.400 5.400 15.400
In non-
conductive
status
8.200 36.400 8.200 36.400 8.200 36.400 5.300 15.300
BKCMP=
(S1) (S2) (D)
n
n=1 15.300 36.100 15.300 36.100 15.300 36.100 8.200 22.600
n=96 64.500 85.500 64.500 85.500 64.500 85.500 57.400 72.500
BKCMP<>
(S1) (S2) (D)
n
n=1 15.300 36.100 15.300 36.100 15.300 36.100 8.200 22.500
n=96 66.600 87.500 66.600 87.500 66.600 87.500 59.500 74.500
BKCMP>
(S1) (S2) (D)
n
n=1 15.300 36.100 15.300 36.100 15.300 36.100 8.200 23.100
n=96 66.600 87.500 66.600 87.500 66.600 87.500 59.500 74.400
BKCMP<=
(S1) (S2) (D)
n
n=1 15.300 36.100 15.300 36.100 15.300 36.100 8.200 22.500
n=96 64.500 85.500 64.500 85.500 64.500 85.500 57.400 72.400
Category Instruction Condition (device) Processing time (s)
Q00UJCPU Q00UCPU Q01UCPU Q02UCPU
Min. Max. Min. Max. Min. Max. Min. Max.

Table of Contents

Related product manuals