12 DATA USED FOR POSITIONING CONTROL
12.8 Control Data
537
12
[Cd.147] Speed limit value at continuous operation to torque control mode
Set the speed limit value at continuous operation to torque control mode.
Set a value within the following range:
*1 When "[Pr.83] Speed control 10 multiplier setting for degree axis" is valid, the setting range is -2000000000 to 2000000000 ( 10
-2
degree/min).
Fetch cycle: Operation cycle (At continuous operation to torque control mode)
Setting value
Set with a decimal.
Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 392 Control data
[Cd.148] Acceleration time at continuous operation to torque control mode
Set the acceleration time at continuous operation to torque control mode. (Set the time for the speed to increase from "0" to
"[Pr.8] Speed limit value".)
0 to 65535 (ms)
Fetch cycle: At control mode switching
Setting value
Set with a decimal.
Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 392 Control data
[Pr.1] Unit setting mm ( 10
-2
mm/min) inch ( 10
-3
inch/min) degree
*1
( 10
-3
degree/min) pulse (pulse/s)
Setting range -2000000000 to 2000000000 -2000000000 to 2000000000 -2000000000 to 2000000000 -1000000000 to 1000000000
[Cd.147] Speed limit value at
continuous operation
to torque control mode
Actual value
Conversion into an
integer value
× 10
m
R
Setting value
Unit conversion table ([Cd.147])
m
mm/min
inch/min
2
3
3
*
degree/min
0
pulse/s
Unit
*: When "[Pr.83] Speed control
10 × multiplier setting for
degree axis" is valid: "2"
Setting
value
K
Acceleration time at
continuous operation to
torque control mode (ms)
0 to 65535