Setting parameters
10/05 AWB8230-1541GB
146
PNU Name RUN b031
= 10
Display and value range Manipulated
variable
Remark
C091 Debug mode j j 00: Disabled (do not show parameter) 00
01: Enabled (display parameter)
C092 Indication, DC link
voltage
j j 0000 - FFFF
(do not change)
1200
C093 Indication, debug
mode
j j 0000 - FFFF
(do not change)
1200
C094 Indication, debug
mode (bit)
j j Address range 0000 – FFFF h 0 – 7 bit selected
(do not change)
1200
C095 Selected debug
mode
j j
00: Internal
01: IO range
00
C121 O compensation 0 - 65535 1. Factory default
setting
C122 OI compensation
0 - 65535 1. Factory default
setting
C123 OI zero
compensation
––
0 - 65535 1/10 Factory default
setting
C190 Test safety mode
00: OFF
01: ON
C193 Test flag 0 - 65535
C194 Test flag mode 00: Standard
01: Test routine mode
02: Function routine mode
C195 Initialization,
country-coding
––00: Japan
01: Europe
02: USA
C196 Assigned motor
rating
––200 V class
Japan, USA: 0.2; 0.4; 0.75; 1.5; 2.2; 3.7; 5.5; 7.5 [HP]
Europe: 0.2; 0.4; 0.55; 0.75; 1.1; 1.5; 2.2; 3.0; 4.0;
5.5; 7.5 [kW]
Factory default
setting
400 V class
Japan: 0.2; 0.4; 0.75; 1.5; 2.2; 3.7; 5.5; 7.5 [HP]
USA: 0.2; 0.4; 0.75; 1.1; 1.5; 2.2; 3.7; 4.0; 5.5; 7.5
[HP]
Europe: 0.2; 0.4; 0.55; 0.75; 1.1; 1.5; 2.2; 3.0; 4.0;
5.5; 7.5 [kW]
C197 Voltage class,
coding
––
00: 200 V class
01: 400 V class
Factory default
setting
d101 Indication, output frequency 0.0 – 400.0 0.1 [Hz]
d102 Indication, DC link voltage 0.0 – 999.9 (DC+/DC–) 0.1 [V]
d104 Indication, thermal load on electronics 0.0 – 100.0 0.1 [%]
d106 Indication, MCU number 0000 – 9999 1
d107 Indication, IO MCU number 0000 – 9999 1 -
d109 Indication, maximum DC link voltage
0.0 – 999.9 0.1 [V]

Table of Contents