Using the DF51
10/05 AWB8230-1541GB
56
Quick parameter selection
To activate quick selection mode, press both arrow keys Í and Ú
at the same time in parameterization mode. The first digit of the
digital display then flashes. To change its value (A, b, C, d, F, H),
use the arrow keys (Í or Ú). Each letter corresponds to an area
in the main menu.
To change to the second, third and fourth digit of the display, press
the Enter key each time. The active digit flashes in each case. To
change the value of the active digit (0 to 9), use the arrow keys
(Í or Ú).
When you press Enter again after the fourth digit, the entered
parameter is called up. If the number you have entered does not
exist, the last valid PNU is selected again when you press the Enter
key.
To go back to the last valid PNU from the first digit, press the PRG
key.
Menu overview
The illustration below shows the structure of the parameter levels.
Figure 57: 7-segment display
1234
Figure 58: Parameter structure
a Change between the four-position digital display and the display
parameters
b Select the display parameter
c Selection in the main menu
d Select the basic parameter
e Change between main menu and the parameter level
f Select a parameter (PNU)
g Change between parameters (PNU) and value range
h Select in value range (digits 0 to 9, functions)
i Save values and return to parameter (PNU)
j Return to main menu
PRG
PRG
PRG
PRG PRG
ENTER
EEPROM
PRG
PRG
ENTER
a
c
f
e
g
b
h
d
j
i