10/05 AWB8230-1541GB
74
Acceleration and deceleration characteristic
Control signal terminal overview (input)
Table 21 provides an overview of the digital and analog control
signal terminal inputs. For a detailed description of each function,
see from page 104.
Table 21: Brief description of the functions (digital and analog inputs)
PNU Name RUN b031
= 10
Value Function DS
A097 Acceleration
time,
characteristic
– – Here, you can set a linear or an S-curve acceleration characteristic for motor acceleration
(first and second time ramp):
00
00 linear
01 S curve
A098 Deceleration
time,
characteristic
– – 00 linear 00
01 S curve
00
01
f
t
Name Value
1)
Function Description
Parameterizable digital inputs 1 to 6 Parameterizing PNU C001 to C006
FWD 00 Clockwise rotation
(RUN/STOP)
REV 01 Anticlockwise rotation
(RUN/STOP)
FWD input closed: motor starts up with a clockwise rotating field.
FWD input open: controlled motor deceleration to stop (clockwise rotating field).
REV input: As for FWD, but with anticlockwise rotating field
FWD and REV inputs closed simultaneously: Motor does not start or controlled motor deceleration
to stop.
1) To activate the function, enter this value in the corresponding parameter.
REV
FWD
P2412
FWD
f
REV
M