Setting parameters
10/05 AWB8230-1541GB
84
1
Digital input 4
C005 = 09 (2CH)
When FWD (digital input 1) is deactivated, the drive is slowed with the deceleration ramp specified in PNU F003. To change to another
deceleration ramp (PNU A093), activate 2CH (second time ramp) (a section “Changing over time ramps”, page 93).
2
Digital input 3
C003 = 08 (SET)
Digital input 5
C004 = 09 (2CH)
If the second parameter set (SET) is activated at motor stop, activation of 2CH (second time ramp) causes a changeover of the deceleration ramp
of F003 to a third deceleration ramp (PNU A293).
3
Digital input 3
C003 = 53 (SP-SET)
Digital input 5
C004 = 09 (2CH)
If, instead of SET, the second parameter set SP-SET is activated, you can change over between all three deceleration ramps in RUN mode. You
can therefore choose between three different, individually adjustable deceleration ramps to slow down the motor.
2CH
FWD
P2414
f
t
F003
A093
FWD/REV
2CH
2CH
FWD
SET
P24134
FWD/REV
f
t
SET
2CH
F003
A293
2CH
FWD
SP-SET
P24134
f
F003
A093
A293
FWD/REV
2CH
SP-SET