265
cpqHe3FltTolFanRedundancyLost
The fault-tolerant fans have lost
redundancy.
A fault-tolerant fan has been inserted.
A fault-tolerant fan has been removed.
Temperature exceeded on the server.
cpqHe3TemperatureDegraded
The temperature status has been set to
Degraded, and the temperature is
outside the normal operating range.
Depending on the system
configuration, this system might be
shut down.
The temperature status has been set to
OK.
cpqHe4FltTolPowerSupplyOk
The fault-tolerant power supply
condition has been reset to OK.
cpqHe4FltTolPowerSupplyDegraded
The fault-tolerant power supply
condition has been set to Degraded.
cpqHe4FltTolPowerSupplyFailed
The fault-tolerant power supply
condition has been set to Failed.
cpqHeResilientMemMirroredMemoryEngaged
The Advanced Memory Protection
subsystem has detected a memory
fault. Mirrored Memory has been
activated.
cpqHe3FltTolPowerRedundancyRestore
The fault-tolerant power supplies have
returned to a redundant state.
cpqHe3FltTolFanRedundancyRestored
The fault-tolerant fans have returned to
a redundant state.
cpqHeManagementProcInReset
The management processor is
resetting.
The management processor is ready.
cpqHe5CorrMemReplaceMemModule
Memory errors have been corrected.
Replace the memory module.
cpqHe4FltTolPowerSupplyACpowerloss
The fault-tolerant power supply in the
specified chassis and bay reported AC
power loss.
Table Continued