Basic System Configuration Guide System Management
Edition: 01 3HE 11010 AAAC TQZZA 361
tod-1pps
Syntax tod-1pps
Context config>system>time
Description This command enables the context to create or modify tod-1pps connector parameters.
message-type
Syntax message-type {ct | cm | irig-b002-b122 | irig-b003-b123 | irig-b006-b126 | irig-b007-b127}
no message-type
Context config>system>time>tod-1pps
Description This command specifies the format for the Time of Day message that is transmitted out the
time of day (ToD) or ToD/PPS Out port on the following:
• 7705 SAR-M
• 7705 SAR-H
• 7705 SAR-A
• 7705 SAR-Ax
• 7705 SAR-X
This Time of Day message output is only available when the router is configured with an
active IP PTP slave clock or boundary clock. It is not available when Time of Day is recovered
from an Ethernet PTP clock or integrated GNSS.
Default no message-type
Parameters ct — China Telecom; not available on the 7705 SAR-H
cm — China Mobile; not available on the 7705 SAR-H
irig-b002-b122 | irig-b003-b123 | irig-b006-b126 | irig-b007-b127 — specifies IRIG-B
message format; available on the 7705 SAR-H only
output
Syntax [no] output
Context config>system>time>tod-1pps
Description This command specifies whether the 1pps output is enabled. When disabled, neither the
1pps nor the RS-422 serial port is available.
Default no output