EasyManua.ls Logo

Nordson ProBlue Flex - Connect a Compressed Air Supply

Nordson ProBlue Flex
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ProBlue Flex OEM Users Guide
62
Part 1129255_01
E 2020 Nordson Corporation
LED Description Color
DS1 24V Enable for external devices
S Green: Enabled
S Amber: enabled with overload condition
S Red: Disabled with no load connected
S Off: Disabled
DS2 CPU Reset
S Off: Normal operation
S Red: CPU reset in progress
DS3 3.3V Supply Status
S Green: Normal operation
S Amber or Red: Fault in 3.3V regulator
S Off: Missing 24VDC
DS4 Sensor quadrature status. Indicates the
quadrature relationship between the two flow
meter sensors.
Cycles between off, green, amber, and red
DS5 Flowmeter Sensor B Status
S Green: Flow detected
S Amber: Sensor connected, but no flow
detected
S Red: Sensor failure or not connected
DS6 Flowmeter Sensor A Status
S Green: Flow detected
S Amber: Sensor connected, but no flow
detected
S Red: Sensor failure or not connected
DS7 General Status LED Indicates the overall status of the Flow PCA
DS8 24VDC Input
S Green: 24VDC present
S Red: 24VDC connected backwards
DS9 Trigger 2 State
S Green: Trigger #2 is being driven
S Off: Trigger #2 is not being driven
DS10 Trigger 1 State
S Green: Trigger #1 is being driven
S Off: Trigger #1 is not being driven
DS11 Encoder quadrature status. Indicates the
quadrature relationship between the two
encoder inputs or the state of a single phase
encoder input.
For quadrature encoders will cycle between off,
green, amber, and red. For single phase
encoders will toggle between off and green.
DS12 Ejector State
S Amber: Ejector active
S Off: Ejector inactive

Table of Contents