8
Min.:
7
456
123
.0
230Max.:
40
Min.:
789
456
123
450Max.:
100
Maximum temperature setpoint
°C
230
System ready delay time
min
0
Operation
4-52
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
Melter (contd.)
Screen 2: Units, Ready Delay Time, Password, Service
Interval, Field Bus
(contd.)
Note on Switching
The limits Min and Max are not converted exactly; they are rounded to a
whole value.
If a setpoint is near a limit, switching back and forth repeatedly between the
units can result in slight deviations from the initial input.
Fig. 4-59 Example °C and °F
Maximum Temperature Setpoint
This parameter is used to adapt the melter to the maximum material
processing temperature permitted.
Setting range
Standard melter
40 to 230 °C 100 to 450 °F
Fig. 4-60 V14a
System Ready Setup
The system ready delay time is the time after which all components have
reached their setpoint temperatures (A) and before the system indicates
readiness (B). This additional time allows the material to reach a thermally
homogenous state.
Fig. 4-61 V17
System ready
delay time
Time
Temperature
(A) (B)
The system ready delay time, if activated, runs after every heatup phase
(status display).
0 min

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nordson VersaBlue VB Series and is the answer not in the manual?

Nordson VersaBlue VB Series Specifications

General IconGeneral
BrandNordson
ModelVersaBlue VB Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals