3-24
3-1 Driver Specifications
Accurax G5 AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
3
Specifications
Control Input Circuits
Speed Command Input, Torque Command Input and Speed Limit Input
The maximum allowable input voltage is ± 10 V for each input. The VR must be 2 kΩ with B
characteristics and 1/2 W minimum. R must be 200 Ω and 1/2 W minimum.
Position Command Pulse (Line Receiver Input)
When connecting with a line driver and a line receiver, up to 4 Mpps will be available.
(+CWLD: 44, CWLD: 45, +CCWLD: 46, CCWLD: 47)
The shielded twisted-pair cable should not exceed 20 m in length.
15
17
1000 pF
470pF
470 pF
1000 pF
Maximum
input voltage
±10 V
47 kΩ 47 kΩ
47 kΩ
20 kΩ
20 kΩ
47 kΩ
REF/TREF1/VLIM14
Maximum
input voltage
±12 V
14 kΩ
20 kΩ
10 kΩ
20 kΩ
TREL2/PCL/NCL16,18
1000 pF
1000 pF
44,46
45,47
13
Controller
+
120 Ω
2 kΩ
2 kΩ
20 kΩ
20 kΩ
Applicable
line driver
AM26LS31A or
equivalent
Applicable
line driver
AM26C32 or
equivalent

Table of Contents