8-26
8-4 Analog Control Parameters
Accurax G5 AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
  8
Parameters Details
8-4 Analog Control Parameters
Explanation of Set Values
 Select the speed command when using speed control. The driver has internally set speed function
that can be used to easily achieve speed control by using contact inputs.
For details on internally set speed function, refer to "5-4 Internally Set Speed Control" (P.5-19).
Explanation of Set Values
 Set to reverse the polarity of the speed command input (REF: CN1 pin 14). This is used to change
the motor rotation direction without changing the polarity of host device command signals.
The default setting for this parameter is 0. By rotating to the reverse direction with the +command
keeps the compatibility with all OMNUC W-Series Servo Drives.
The operation of the Servomotor may be abnormal if the polarity of the speed command signal from the Position
Control Unit does not agree with the setting of this parameter when the Servo Drive system is comprised of the
combination of the Servo Drive set to the SPEED CONTROL mode and an external Position Control Unit.
Pn300
Command Speed Selection
Setting 
range
0 to 3 Unit −
Default 
setting
0
Power OFF 
and ON
−
Speed
Set value
Explanation
0 Analog speed command
1 No. 1 Internally Set Speed to No. 4 Internally Set Speed (Pn304 to Pn307)
2
No. 1 Internally Set Speed to No. 3 Internally Set Speed (Pn304 to Pn306), analog speed command
3 No. 1 Internally Set Speed to No. 8 Internally Set Speed (Pn304 to Pn311)
Pn301
Speed Command Direction Selection
Setting 
range
0 to 1 Unit −
Default 
setting
0
Power OFF 
and ON
−
Speed
Set value
Explanation
0
Method for designating the direction for the speed command: By analogue command polarity
1
Method for designating the direction for the speed command: By digital input VSIGN
Command 
Speed 
Selection 
(Pn300)
Speed 
Command 
Direction 
Selection 
(Pn301)
Analog Speed 
Command 
Rotation 
Direction 
Switching 
(Pn303)
Analog speed 
command (REF)
Speed 
command 
sign 
selection 
(VSIGN)
Motor 
rotation 
direction
Conversion 
graph
0
0
0
+Voltage (0 to 10 V)
Not affected
Forward 
direction
Refer to 
Figure A
-Voltage (-10 to 0 V)
Not affected
Reverse 
direction
1
+Voltage (0 to 10 V)
Not affected
Reverse 
direction
Refer to 
Figure B
-Voltage (-10 to 0 V)
Not affected
Forward 
direction
1
Not 
affected
+Voltage (0 to 10 V)
OFF
Forward 
direction
Refer to 
Figure C
-Voltage (-10 to 0 V)
+Voltage (0 to 10 V)
ON
Reverse 
direction
-Voltage (-10 to 0 V)