8-27
8-4 Analog Control Parameters
Accurax G5 AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
8
Parameters Details
Set the relation between the voltage applied to the speed command input (REF: CN1 pin 14) and the motor speed.
For details on speed control, refer to "5-2 Speed Control" (P.5-8).
Explanation of Set Values
10
10
Input voltage
Speed command
Speed command
10
10
Input voltage
Speed command Speed command
10
10
Input voltage
10
10
Input voltage
VSIGN ON VSIGN OFF
Figure A
Figure B
Figure C
Pn302
Speed Command Scale
Setting
range
0 to 2,000 Unit (r/min)/V
Default
setting
500
Power OFF
and ON
Speed
Torque
Pn303
Analog Speed Command Rotation Direction Switching
Setting
range
0 to 1 Unit
Default
setting
1
Power OFF
and ON
Speed
Set value
Explanation
0
Rotation direction is changed by analog speed command (REF) voltage.
+Voltage: Forward direction
-Voltage: Reverse direction
1
Rotation direction is changed by analog speed command voltage.
+Voltage: Reverse direction
-Voltage: Forward direction
Pn304
No. 1 Internally Set Speed
Setting
range
20,000 to 20,000 Unit r/min
Default
setting
0
Power OFF
and ON
Speed

Table of Contents