8-59
8-7 Special Parameters
Accurax G5 AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
8
Parameters Details
8-7 Special Parameters
Set the input gain for analog torque feed forward.0 to 9 will disable the function.
Set the command speed during JOG trial operation (speed control).
Set effective time of gain 3 of 3-step gain switching.
Set gain 3 as a multiple of gain 1.
Set offset torque to add to torque command.
Set the value to add to the torque command in the forward direction operation.
Set offset torque to add to torque command for reverse direction operation.
Set each function per bit.
Set the decimal value that has been converted from bit.
[Example]
Instantaneous speed observer function: enabled
Disturbance observer function: enabled
Disturbance observer operation setting: enabled at all time
Inertia ratio switching function: disabled
Electric current response improvement function: enabled.
Pn600
Analog Torque Feed-forward Gain Setting
Setting range
0 to 100 Unit 0.1 V/100%
Default setting
0
Power OFF and ON
Position
Speed
Full closing
Pn604
Jog Speed
Setting range
0 to 500 Unit r/min
Default setting
300
Power OFF and ON
All
Pn605
Gain 3 Effective Time
Setting range
0 to 10,000 Unit 0.1 ms
Default setting
0
Power OFF and ON
Position
Full closing
Pn606
Gain 3 Ratio Setting
Setting range
100 to 1,000 Unit %
Default setting
100
Power OFF and ON
Position
Full closing
Pn607
Torque Command Value Offset
Setting range
100 to 100 Unit %
Default setting
0
Power OFF and ON
All
Pn608
Forward Direction Torque Offset
Setting range
100 to 100 Unit %
Default setting
0
Power OFF and ON
All
Pn609
Reverse Direction Torque Offset
Setting range
100 to 100 Unit %
Default setting
0
Power OFF and ON
All
Pn610
Function Expansion Setting
Setting range
0 to 63 Unit
Default setting
0
Power OFF and ON
Position
Bit Function
Set value
0 1
bit 0 Instantaneous speed observer function Disabled Enabled
bit 1 Disturbance observer function Disabled Enabled
bit 2 Disturbance observer operation setting Enabled at all time
Only when gain 1 is selected
bit 3 Inertia ratio switching function Disabled Enabled
bit 4
Electric current response improvement function
Disabled Enabled

Table of Contents