3-55
3-3 Motor Specifications
Accurax G5 AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
   3
Specifications
3-3 Motor Specifications
The following Accurax G5 AC Servomotors are available.
 3,000-r/min motors
 2,000-r/min motors
 1,000-r/min motors
There are various options available, such as models with brakes, Decelerators, or different
shaft types.
Select a Servomotor based on the mechanical system's load conditions and the installation
environment.
General Specifications
*1. 
The amplitude may be amplified by machine resonance. Do not exceed 80% of the specified value for extended periods of time.
Note 1. Do not use the cable when it is laying in oil or water.
Note 2. Do not expose the cable outlet or connections to stress due to bending or the weight of the cable itself.
Item
3,000-r/min motors
1,000-r/min motors
2,000-r/min motors 
50 to 750 W 1 to 5 kW 900 W to 5 kW
Ambient operating 
temperature and 
operating humidity
0 to +40°C, 20% to 80% RH 
(with no condensation)
0 to +40°C, 20% to 85% RH (with no condensation)
Storage ambient 
temperature and humidity
−20 to +65°C, 20% to 8 0% 
RH (with no condensation)
Guaranteed maximum 
temperature of 80°C (72 
hours at normal 
temperature)
−20 to +65°C, 20% to 85% RH (with no condensation)
Guaranteed maximum temperature of 80°C (72 hours at 
normal temperature)
Operating and storage 
atmosphere
No corrosive gases
Vibration resistance *
1
Acceleration of 49 m/s
2
24.5 m/s
2
 max. in X, Y, and Z directions when the motor is stopped
Impact resistance
Acceleration of 98 m/s
2
 max. 3 times each in X, Y, and Z directions
Insulation resistance Between power terminal and FG terminal: 20 MΩ min. (at 500 VDC Megger)
Dielectric strength 1,500 VAC between power terminal and FG terminal (sensed current 10 mA) for 1 min 
(voltage 200 V)
1,800 VAC between power terminal and FG terminal (sensed current 10 mA) for 1 min 
(voltage 400 V)
1,000 VAC between brake terminal and FG terminal (sensed current 10 mA) for 1 min
Protective structure IP67 (except for through-shaft parts and motor and encoder connector pins)
EC 
directive
EMC 
directive
EN 55011 class A group 1
EN61000-6-2, IEC61800-3 and IEC61326-3-1
Low 
voltage
directive
EN60034-1/-5
UL standards UL1004
CSA standards CSA22.2 No. 100