3-41
3-1 Driver Specifications
Accurax G5 AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
   3
Specifications
Control Output Details
Control Output Sequence
*1. In this section, the hardware inputs the servo ON signal, but the signal is not accepted.
*2. The servo ready completed output turns ON the moment the conditions of MPU initialization completed and main 
circuit power supply establishment are both satisfied.
*3. Operation of the protective function starts approx. 1.5 seconds after the start of MPU initialization following an 
establishment of internal control power supply. Make sure all I/O signals which connect to the amplifier (especially 
forward/reverse direction, drive prohibition input and external scale input) are established before operation of the 
protective function starts. Also, you can increase this time with Pn618 "Power Supply ON Initialization Time."