3-26
3-1 Driver Specifications
Accurax G5 AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
3
Specifications
Open Collector Input
External 24-V power supply without a Current Limit Resistor (200 kpps maximum) (+24 VCW: 1,
CW: 4, +24 VCCW: 2, CCW: 6)
External control power supply (200 kpps maximum) (+CW: 3, CW: 4, +CCW: 5, CCW: 6)
Select a Current Limit Resistor (R) appropriate for Vcc.32
Precautions for Correct Use
The open collector wiring should not exceed 2 m in length.
10mA
(7 to 15 mA)
VCC R
24 V 2 kΩ (1/2 W)
12 V 1 kΩ (1/2 W)
5 V 0 Ω (short)
Vcc 24 V
1000 pF
Controller Driver
+
220 Ω
2.2 kΩ
2.2 kΩ
Vcc
R
1000 pF
Controller Driver
+
220 Ω
2.2 kΩ
2.2 kΩ
Vcc 1.5
R + 220