EasyManua.ls Logo

Omron ACCURAX G5 - Page 159

Omron ACCURAX G5
553 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-69
3-3 Motor Specifications
Accurax G5 AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
3
Specifications
Use the following Servomotors in the ranges shown in the graphs below. Using outside of
these ranges may cause the motor to generate heat, which could result in encoder malfunction.
• R88M-K05030H/T • R88M-K05030L/S/H/T • R88M-K10030L/S/H/T
(50 W: Without oil seal) (50 W: With oil seal) (100 W: Without oil seal)
• R88M-K10030L/S/H/T • R88M-K20030L/SH/T • R88M-K40030L/S/H/T
(100 W: With oil seal) (200 W: With oil seal) (400 W: Without oil seal)
• R88M-K40030L/S/H/T • R88M-K1K530H/T/F/C • R88M-K2K030H/T/F/C
(400 W: With oil seal) (1.5 kW) (2 kW)
• R88M-K3K030H/T/F/C • R88M-K4K030H/T/F/C • R88M-K5K030H/T/F/C
(3 kW) (4 kW) (5 kW)
Rated torque ratio [%]
Ambient
temperature
[
°
C]
100%
95%
100203040
With brake
Rated torque ratio [%]
100%
70%
60%
100203040
Without brake
With brake
Ambient
temperature
[
°
C]
Rated torque ratio [%]
100%
95%
100203040
With brake
Ambient
temperature
[
°
C]
Rated torque ratio [%]
100%
75%
70%
100203040
Without brake
With brake
Ambient
temperature
[
°
C]
Rated torque ratio [%]
100%
80%
70%
100203040
Without brake
With brake
Ambient
temperature
[
°
C]
Rated torque ratio [%]
100%
90%
100203040
With brake
Ambient
temperature
[
°
C]
Rated torque ratio [%]
100%
75%
100203040
With brake
Ambient
temperature
[
°
C]
Rated torque ratio [%]
100%
85%
100203040
Without brake
With brake
Ambient
temperature
[
°
C]
Rated torque ratio [%]
100%
85%
70%
100203040
Without brake
With brake
Ambient
temperature
[
°
C]
Rated torque ratio [%]
100%
85%
90%
100203040
Without brake
With brake
Ambient
temperature
[
°
C]
Rated torque ratio [%]
100%
85%
90%
100203040
Without brake
With brake
Ambient
temperature
[
°
C]
(N • m)
0 1000 2000
5
10
15
14.3
4.77 4.77
14.3 (2200)
Momentary operation range
Continuous operation range
3000
(r/min)
Power supply voltage
dropped by 10%
6.0
4.0
(2000)
3.2

Table of Contents