3-77
3-3 Motor Specifications
Accurax G5 AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
3
Specifications
2,000-r/min motor (400 VAC)
The following graphs show the characteristics with a 3-m standard cable and a 400-VAC input.
• R88M-K40020F/C (400 W) • R88M-K60020F/C (600 W) • R88M-K1K020F/C (1 kW)
• R88M-K1K520F/C (1.5 kW) • R88M-K2K020F/C (2 kW) • R88M-K3K0F/C (3 kW)
• R88M-K4K020F/C (4 kW) • R88M-K5K020F/C (5 kW)
Use the following Servomotors in the ranges shown in the graphs below. Using outside of
these ranges may cause the motor to generate heat, which could result in encoder malfunction.
• R88M-K5K020H/T/F/C (5 kW)
0 1000 2000
3
6
5.73
1.91
1.91
5.73 (2700)
3000
(r/min)
3.5
(2400)
2.0
1.3
Power supply voltage
dropped by 10%
Continuous operation range
Momentary operation range
(N • m)
0 1000 2000
5
10
8.59
2.86 2.86
8.59 (2400)
3000
(r/min)
4.5
(2100)
1.9
Power supply voltage
dropped by 10%
Continuous operation range
Momentary operation range
(N • m)
0 1000 2000
5
10
15
14.3
4.77 4.77
14.3 (2200)
3000
(r/min)
6.0
4.0
3.2
(2000)
Power supply voltage
dropped by 10%
Continuous operation range
Momentary operation range
(N • m)
10
0
20
21.5
7.16 7.16
21.5 (2300)
1000 2000 3000
(r/min)
10.0
6.0
4.8
(2000)
Power supply voltage
dropped by 10%
Continuous operation range
Momentary operation range
(N • m)
15
0
30
28.6
9.55 9.55
28.6 (2200)
1000 2000 3000
(r/min)
15.0
11.0
6.4
(2000)
Power supply voltage
dropped by 10%
Continuous operation range
Momentary operation range
(N • m)
25
0
50
43.0
14.3 14.3
43.0 (2400)
1000 2000 3000
(r/min)
28.0
20.0
9.5
(2200)
Power supply voltage
dropped by 10%
Continuous operation range
Momentary operation range
(N • m)