3-110
3-4 Cable and Connector Specifications
Accurax G5 AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
3
Specifications
Terminal Block Unit
The Terminal Block Unit connects the servo drive I/O signals (CN1 connector ) for general
purpose. Use the cable (XW2Z-xJ-B24) to connect the Terminal Block Unit to the CN1
connector.
XW2B-50G4 (M3 Screw Terminal Block)
Dimensions
Use 0.3 to 1.25 mm
2
wire (AWG22 to 16).
The wire inlet is 1.8 mm (height) × 2.5 mm (width).
Strip the insulation from the end of the wire for 6 mm as shown below.
Flat cable connector (MIL type plug)
3.5
15.5
45
2-φ3.5
Terminal block
3.5
29.5
5.08
20.5
38.1
(45.3)
157.5
6 mm

Table of Contents