8-22
8-3 Vibration Suppression Parameters
Accurax G5 AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
8
Parameters Details
Set the notch depth of resonance suppression notch filter 2.
Increasing the setting will shorten the notch depth and the phase lag.
Set the notch frequency of resonance suppression notch filter 3.
The notch filter function will be disabled if this parameter is set to 5,000.
Select the notch width of resonance suppression notch filter 3.
Increasing the setting widens the notch width. Normally, use the default set value.
Set the notch depth of resonance suppression notch filter 3.
Increasing the setting will shorten the notch depth and the phase lag.
Set the notch frequency of resonance suppression notch filter 4.
The notch filter function will be disabled if this parameter is set to 5,000.
Select the notch width of resonance suppression notch filter 4.
Increasing the setting widens the notch width. Normally, use the default set value.
Set the notch depth of resonance suppression notch filter 4.
Increasing the setting will shorten the notch depth and the phase lag.
Pn206
Notch 2 Depth Setting
Setting
range
0 to 99 Unit
Default
setting
0
Power OFF
and ON
All
Pn207
Notch 3 Frequency Setting
Setting
range
50 to 5,000 Unit Hz
Default
setting
5000
Power OFF
and ON
All
Pn208
Notch 3 Width Setting
Setting
range
0 to 20 Unit
Default
setting
2
Power OFF
and ON
All
Pn209
Notch 3 Depth Setting
Setting
range
0 to 99 Unit
Default
setting
0
Power OFF
and ON
All
Pn210
Notch 4 Frequency Setting
Setting
range
50 to 5,000 Unit Hz
Default
setting
5000
Power OFF
and ON
All
Pn211
Notch 4 Width Setting
Setting
range
0 to 20 Unit
Default
setting
2
Power OFF
and ON
All
Pn212
Notch 4 Depth Setting
Setting
range
0 to 99 Unit
Default
setting
0
Power OFF
and ON
All
Pn213
Vibration Filter Selection
Setting
range
0 to 3 Unit
Default
setting
0
Power OFF
and ON
Position