8-53
8-6 Extended Parameters
Accurax G5 AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
8
Parameters Details
Select the signal read cycle for control signal (digital input).
Explanation of Set Values
Select the signal confirmation time for alarm reset input signal (RESET).
Explanation of Set Values
When set to 1 or 2, the minimum time width will be as follows.
When set to 3 or 4, the minimum time width will be as follows.
Explanation of Set Values
Enable or disable the pulse prohibition input signal (IPG).
Pn516
Alarm Reset Condition Selection
Setting
range
0 to 1 Unit −
Default
setting
0
Power OFF
and ON
−
All
Set value
Explanation
0 120 ms
1 Follow the Control Input Signal Read Setting (Pn515).
Pn517
Error Counter Reset Condition Selection
Setting
range
0 to 4 Unit −
Default
setting
3
Power OFF
and ON
−
Full closing
Set value
Explanation
0 Disabled
1 Clears the error counter at level when the signal is shorted for 500 μs or longer.
2 Clears the error counter at level when the signal is shorted for 1 ms or longer.
3
Clears the error counter at edge when the signal changes from open to shorted for 100
μ
s or longer.
4
Clears the error counter at edge when the signal changes from open to shorted for 1 ms or longer.
Set value 2: 1 ms or more
Error reset keeps repeating.
Set value 1: 500 μs or more
Error counter
reset input signal
Error is reset once.
Error counter
reset input signal
Set value 4: 1 ms or more
Set value 3: 100 μs or more
Pn518
Command Pulse Prohibition Input Setting
Setting
range
0 to 1 Unit −
Default
setting
1
Power OFF
and ON
−
Position
Full closing
Set value
Explanation
0 Enabled
1 Disabled