EasyManua.ls Logo

Omron ACCURAX G5 - Page 519

Omron ACCURAX G5
553 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12-7
12-1 Connection Examples
Accurax G5 AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
12
Appendix
Connection Example 6: Connecting to SYSMAC CP1H-YxxDT-D
Precautions for Correct Use
Incorrect signal wiring can cause damage to units and the driver.
Leave unused signal lines open and do not wire them.
Do not share the power supply for brakes (24 VDC) with the 24-VDC power supply for controls.
The diode recommended for surge absorption is the RU 2 (Sanken Electric Co., Ltd.) or the
equivalent.
S
CN1 CNA
4
5
6
30
39
7
29
37
11
3
L1
L2
U
V
W
ZCOM
INP
RUN
/ALM
FG
Z
X1
XB
24 VDC
R
T
NFB
ONOFF
X1
MC1
X1
24 VDC
BKIR
25
19
MC1
X1
L3
M
Red
White
Blue
Green/Yellow
R88M-Kx
CN2
Motor power cables
E
24 VDC
Encoder cables
B
Brake cables
XB
CNB
B1
B3
B2
BKIRCOM
10
ALMCOM
36
PL
SUP
MC2
MC1
MC2
MC1 MC2
MC2
ECRST
Reactor
CP1H-Y20DT-D R88-KTx
Output terminal block
CW0+
CW0
CCW0+
CCW0
24-VDC input terminal (+)
Input terminal block
Shell
+CW
CW
+CCW
CCW
+24VIN
Pulse
Output
0
Noise filter
Main circuit power supply
24-VDC input terminal ()
COM(0CH)
Servo error display
Main circuit contact
surge suppressor
Pulse 0 origin input signal (0 word, bit 00)
Pulse 0 origin proximity input signal (0 word, bit 01)
Origin search 0 (101 word, bit 02)
COM (for 101 word, bit 00 to 03)
3-phase 200 to 240 VAC 50/60 Hz
Ground to
100 Ω or less

Table of Contents