12-32
12-2 Parameter List
Accurax G5 AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
12
Appendix
620
External Scale
Phase-Z
Expansion Setting
Set the external scale phase-Z output width. 0 μs 0 to 400 Yes
621
Serial Absolute
External Scale
Phase-Z Setting
Set the phase-Z regeneration position when
the serial absolute external scale is used.
0 Pulse 0 to 2
28
Yes
622
Phase-AB
Regeneration
Method Selection
for External Scale
of Phase-AB
Output Type
Select the regeneration method of pulse
outputs OA and OB when an external scale
of phase AB-output type is used.
0 0 to 1 Yes
0 Without signal regeneration
1 With signal regeneration
623
Disturbance Torque
Compensation Gain
Set the compensation gain for disturbance
torque.
0%
-100 to
100
624
Disturbance Observer
Filter Setting
Set the filter time constant for disturbance
torque compensation.
53
0.01
ms
10 to
2,500
627
Warning Latch
Hold Time
Selection
Select the warning latch time.
0 0 to 1 Yes0 Latch time 10 s
1 Latch time infinite
631
Realtime
Autotuning
Estimated
Speed
Selection
Set the load characteristics estimated speed
when realtime autotuning is enabled.
1 0 to 3
0
Estimation result is finalized when load
estimation stabilizes.
1
For load characteristics change, the estimation
is made at time constant of approx. 7 minutes.
2
For load characteristics change, the estimation
is made at time constant of approx. 4 seconds.
3
For load characteristics change, the estimation
is made at time constant of approx. 2 seconds.
632
REALTIME
AUTOTUNING
CUSTOMIZATIO
N mode Setting
Set the CUSTOMIZATION mode detail for
realtime autotuning.
0
-32,768
to 32,767
633
Absolute Encoder
Initial Pulse
Regeneration
Speed
Set the pulse regeneration speed when the
initial pulse is output.
1000 r/min
1,000 to
3,000
634
Hybrid Vibration
Suppression Gain
Set the hybrid vibration suppression gain
during full closing control.
00.1/s
0 to
30,000
635
Hybrid Vibration
Suppression Filter
Set the hybrid vibration suppression filter
time constant during full closing control.
10
0.01
ms
0 to
6,400
637
Vibration
Detection
Threshold
Set the vibration detection threshold.
If torque vibration that exceeds this setting is
detected, the vibration detection warning will
occur.
00.1%
0 to
1,000
638
Warning Mask
Setting
Set the warning detection mask setting.If
you set the corresponding bit to 1, the
corresponding warning detection will be
disabled.
0
-32,768
to 32,767
Yes
Pn number
Parameter
name
Explanation
Default
setting
Unit
Setting
range
Power
supply
OFF to
ON
Setting