538
Specifications of Basic I/O Units Appendix A
Basic Output Units
Note 1. For details on the connectors included with the Unit, refer to the information provided under Acces-
sories in the tables for Basic I/O Units in the following pages.
2. Although 16 I/O bits (1 word) are allocated, only 8 of these can be used for external I/O. This Unit is
also treated as a 16-point I/O Unit in the I/O tables.
Reading Terminal Connection Diagrams
• I/O terminals in terminal connection diagrams are shown as viewed from the front panel of the Unit.
• Terminal numbers A0 to A9 and B0 to B9 are used in this manual, but they are not printed on all Units.
• A0 to A20 and B0 to B20 are printed on the Units.
Name Specifications Model Number
of bits
allocated
Page
Relay Output Units Terminal block, 250 V AC/24 V DC, 2 A, inde-
pendent contacts
CJ1W-OC201 8 (16)
(See note
2.)
565
Terminal block, 250 V AC/24 V DC, 2 A CJ1W-OC211 16 566
Triac Output Unit Terminal block, 250 V AC, 0.6 A/24 V DC, CJ1W-OA201 8 (16)
(See note
2.)
567
Transis-
tor Out-
put Units
Sinking
outputs
Terminal block, 12 to 24 V DC, 2 A CJ1W-OD201 8 (16)
(See note
2.)
568
Terminal block, 12 to 24 V DC, 0.5 A CJ1W-OD203 8 (16)
(See note
2.)
569
Terminal block, 12 to 24 V DC, 0.5 A CJ1W-OD211 16 570
Fujitsu-compatible connector, 12 to 24 V DC,
0.5 A
CJ1W-OD231 32 571
MIL connector, 12 to 24 V DC, 0.5 A CJ1W-OD233 32 574
Fujitsu-compatible connector, 12 to 24 V DC,
0.3 A
CJ1W-OD261 64 575
MIL connector, 12 to 24 V DC, 0.3 A CJ1W-OD263 64 577
Sourcing
outputs
Terminal block, 24 V DC, 2 A, load short-cir-
cuit protection, line disconnection detection
CJ1W-OD202 8 (16)
(See note
2.)
578
Terminal block, 24 V DC, 0.5 A, load short-
circuit protection
CJ1W-OD204 8 (16)
(See note
2.)
579
Terminal block, 24 V DC, 0.5 A, load short-
circuit protection
CJ1W-OD212 16 580
MIL connector, 24 V DC, 0.5 A, load short-
circuit protection
CJ1W-OD232 32 581
MIL connector, 12 to 24 V DC, 0.3 A CJ1W-OD262 64 584
About Contact Output Units 586
Load Short-circuit Protection and Line Disconnection Detection for CJ1W-OD202 588
Load short-circuit protection for CJ1W-OD204/OD212/OD232/MD232 590