39
CQM1 Interrupt Functions Section 1-5
INI(61), PRV(62), CTBL(63), SPED(64), PULS(65), PWM(––), PLS2(––)
and ACC(––)
The following methods can be used to circumvent this limitation:
Method 1 All interrupt processing can be masked while the instruction is being exe-
cuted.
Method 2 Execute the instruction again in the main program.
This is the program section from the main program:
This is the program section from the interrupt subroutine:
@INT(89)
000
100
000
@PLS2(––)
000
001
DM 0010
@INT(89)
000
200
000
@PRV(62)
002
001
DM 0000
@CTBL(63)
000
001
DM 0000
RSET LR 0000
SBN(92) 000
@CTBL(63)
000
001
DM 0000
25313
25313
LR
0000