19
G9SP-series Controllers Section 2-1
Standard Output Specifications of G9SP-N10S
Input Wiring
Devices with Contact Outputs
A devices with a contact output, such as an emergency stop pushbutton or
safety limit switch, is input to the G9SP-series Controller using a Safety Input
terminal (Si) and Test Output terminal (To).
The total length of cable connected to one Test Output must be 600 m or less.
Devices with PNP Semiconductor Outputs (Current-sourcing Outputs)
The signal from a device with a PNP semiconductor output, such as a light
curtain, is input to a Safety Input terminal (Si). Check the specifications of the
connected device for the maximum cable length.
Item Specification
Output type Sourcing outputs (PNP)
ON residual voltage 1.5 V max. (between outputs and V2)
Rated output current 100mA max.
To
Si
G9SP
V1
G1
24 VDC
6 mA t
yp
To0
Si0
G9SP
Si1
L
1
L
2
L
3
L
4
L
1
+L
2
+L
3
+L
4
600m
Si
G9SP
V1
G1
24 VDC
6 mA t
yp
Device with PNP
semiconductor outpu
t