Servicing Memory 83
■ If the fault is a host-detected fault (displays a UUID), continue to Step 4. For
example:
■ If the fault was detected by POST and resulted in the DIMM being disabled,
you will see something similar to the following output:
In most cases, the replacement of the faulty DIMM is detected when the SP is
power cycled. In this case, the fault is automatically cleared. If the fault is still
displayed by the show faulty command, then use the set command to enable
the DIMM and clear the fault.
Example:
4. Verify the repair.
a. Set the virtual keyswitch to diag so that POST will run in Service mode.
-> show faulty
Target | Property | Value
--------------------+------------------------+--------------------------------
/SP/faultmgmt/0 | fru | /SYS/MB/CMP0/BOB0/CH0/D0
/SP/faultmgmt/0 | timestamp | Dec 14 22:43:59
/SP/faultmgmt/0/ | sunw-msg-id | SUN4V-8000-DX
faults/0 | |
/SP/faultmgmt/0/ | uuid | 3aa7c854-9667-e176-efe5-e487e520
faults/0 | | 7a8a
/SP/faultmgmt/0/ | timestamp | Apr 24 22:43:59
faults/0 | |
-> show faulty
Target | Property | Value
--------------------+------------------------+--------------------------------
/SP/faultmgmt/0 | fru | /SYS/MB/CMP0/BOB1/CH0/D0
/SP/faultmgmt/0 | timestamp | Apr 24 16:40:56
/SP/faultmgmt/0/ | timestamp | Apr 24 16:40:56 faults/0
/SP/faultmgmt/0/ | sp_detected_fault | /SYS/MB/CMP0/BOB1/CH0/D0
faults/0 | | Forced fail(POST)
-> set /SYS/MB/CMP0/BOB0/CH0/D0 component_state=Enabled
-> set /SYS/keyswitch_state=Diag
Set ‘keyswitch_state’ to ‘Diag’