82 Netra SPARC T4-1B Server Module Service Manual • June 2012
5. Push the DIMM into the connector until the ejector tabs lock the DIMM in
place.
If the DIMM does not easily seat into the connector, verify that the orientation of
the DIMM is correct. Never apply excessive force.
6. Return the server module to operation.
See “Returning the Server Module to Operation” on page 117
7. Perform one of the following tasks to verify the DIMM:
■ Verify a replacement DIMM. See “Clear the Fault and Verify the Functionality
of the Replacement DIMM” on page 82.
■ Verify additional memory. See “Verify DIMM Functionality” on page 86.
Related Information
■ “Remove a DIMM” on page 80
■ “DIMM Configuration” on page 77
▼ Clear the Fault and Verify the
Functionality of the Replacement
DIMM
1. Ensure that the following conditions are met:
■ The server module is in Standby mode (installed in a powered modular system,
but the server module’s host is not started).
See “Set the Server Module to a Ready-to-Remove State” on page 60.
■ You have connectivity to the SP.
See “Access the SP (Oracle ILOM)” on page 15
2. Access the Oracle ILOM prompt.
See “Access the SP (Oracle ILOM)” on page 15.
3. Determine how to clear the fault.
The method you use to clear a fault depends on how the fault is identified by the
show faulty command.
Examples: