EasyManua.ls Logo

Oracle SPARC T7-2 - Page 157

Oracle SPARC T7-2
188 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Reactivate RAID Volumes
ok 0 activate-volume
Volume 0 is now activated
Note - For more information on configuring hardware RAID on the server, refer to Servers
Administration.
8.
Unselect the SCSI device.
ok unselect-dev
9.
Confirm that you reactivated the volume.
ok probe-scsi-all
/pci@308/pci@1/usb@0/hub@1/storage@3
Unit 0 Disk smiMICRON eUSB DISK 1112
.
/pci@308/pci@1/usb@0/hub@1/storage@1
Unit 0 Removable Read Only device SUNRemote ISO CDROM1.01
.
/pci@308/pci@1/usb@0/hub@5/device@4/storage@0
Unit 0 Removable Read Only device TEAC DV-W28S-C LT11
.
/pci@303/pci@1/scsi@0
.
FCode Version 1.00.64, MPT Version 2.05, Firmware Version 5.05.00.00
Target 9
Unit 0 Disk HGST H101860SFSUN600G A770 1172123568 Blocks, 600 GB
SASDeviceName 5000cca02f0a1560 SASAddress 5000cca02f0a1561 PhyNum 0
.
Target 389 Volume 0
Unit 0 Disk LSI Logical Volume 3000 583983104 Blocks, 298 GB
VolumeDeviceName 33b2999bca4dc677 VolumeWWID 03b2999bca4dc677
/pci@301/pci@1/scsi@0
.
FCode Version 1.00.64, MPT Version 2.05, Firmware Version 5.05.00.00
10.
Set the auto-boot? OpenBoot PROM variable to true so the server boots the OS
when powered on.
ok setenv auto-boot? true
11.
Reboot the server.
Servicing the Motherboard 157