Reactivate RAID Volumes
ok 0 activate-volume
Volume 0 is now activated
Note - For more information on configuring hardware RAID on the server, refer to Servers
Administration.
8.
Unselect the SCSI device.
ok unselect-dev
9.
Confirm that you reactivated the volume.
ok probe-scsi-all
/pci@308/pci@1/usb@0/hub@1/storage@3
Unit 0 Disk smiMICRON eUSB DISK 1112
.
/pci@308/pci@1/usb@0/hub@1/storage@1
Unit 0 Removable Read Only device SUNRemote ISO CDROM1.01
.
/pci@308/pci@1/usb@0/hub@5/device@4/storage@0
Unit 0 Removable Read Only device TEAC DV-W28S-C LT11
.
/pci@303/pci@1/scsi@0
.
FCode Version 1.00.64, MPT Version 2.05, Firmware Version 5.05.00.00
Target 9
Unit 0 Disk HGST H101860SFSUN600G A770 1172123568 Blocks, 600 GB
SASDeviceName 5000cca02f0a1560 SASAddress 5000cca02f0a1561 PhyNum 0
.
Target 389 Volume 0
Unit 0 Disk LSI Logical Volume 3000 583983104 Blocks, 298 GB
VolumeDeviceName 33b2999bca4dc677 VolumeWWID 03b2999bca4dc677
/pci@301/pci@1/scsi@0
.
FCode Version 1.00.64, MPT Version 2.05, Firmware Version 5.05.00.00
10.
Set the auto-boot? OpenBoot PROM variable to true so the server boots the OS
when powered on.
ok setenv auto-boot? true
11.
Reboot the server.
Servicing the Motherboard 157