Verify the Fan Board
8.
Reinstall all fan modules.
See “Remove a Fan Module” on page 79.
9.
Reinstall all memory risers.
See “Install a Memory Riser” on page 106.
10.
Return the server to operation.
See “Returning the Server to Operation” on page 171.
Note - Authorized service personnel might need to reprogram the product serial number on
the fan board. This number is used for service entitlement and warranty coverage. The correct
product serial number is located on a label on the front of the chassis.
Related Information
■
“Remove the Fan Board” on page 141
■
“Verify the Fan Board” on page 145
Verify the Fan Board
1.
At the Oracle ILOM prompt, start the fault management shell.
-> start /SP/faultmgmt/shell
Are you sure you want to start /SP/faultmgmt/shell (y/n)? y
faultmgmtsp>
2.
Type fmadm faulty to check for faults.
■
If faults are reported, see “Detecting and Managing Faults” on page 29 .
■
If no faults are reported, then the fan board has been replaced successfully.
Related Information
■
“Install the Fan Board” on page 143
■
“Remove the Fan Board” on page 141
Servicing the Fan Board 145