Interpreting LEDs
Related Information
“Rear Panel Controls and LEDs” on page 38
“Checking for Faults” on page 29
Rear Panel Controls and LEDs
No. LED Icon or Label Description
1 PS AC OK LED AC Indicates these conditions:
Off – No AC power applied to this power supply.
Green steady on – AC power is applied to this power supply and is
within specifications.
Amber steady on – AC power is applied to this power supply and
is below 85V.
2 PS DC OK LED (green) Indicates these conditions:
Off – 12V DC output from this power supply is disabled or not
within specification.
Steady on – 12V DC output from this power supply is present and
within specifications.
3 PS Fault LED (amber) Indicates these conditions:
Off – Steady state, no service action is required.
Steady on – A fault has been detected on this power supply.