Servicing the Battery
The battery is located inside the chassis. See “Motherboard Component Locations” on page 21.
The battery maintains system time when the server is powered off and disconnected from AC
power. If the IPMI logs indicate a battery failure, replace the battery.
Caution - Ensure that all power is removed from the server before removing or installing
the battery. You must disconnect the power cords from the server before performing these
procedures.
“Replace the Battery” on page 117
Related Information
“Detecting and Managing Faults” on page 29
“Preparing for Service” on page 47
“Disconnect Power Cords” on page 56
Replace the Battery
1.
Prepare the host for battery replacement.
To correctly reset the date and time before replacing a battery, you must revent the host from
automatically powering on and disable any NTP connections.
a.
Check the HOST_AUTO_POWER_ON property.
-> show /SP/policy HOST_AUTO_POWER_ON
Properties:
HOST_AUTO_POWER_ON = enabled
b.
If enabled, set the HOST_AUTO_POWER_ON property to disabled.
-> set /SP/policy HOST_AUTO_POWER_ON=disabled
Servicing the Battery 117

Table of Contents

Other manuals for Oracle SPARC T7-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oracle SPARC T7-2 and is the answer not in the manual?

Oracle SPARC T7-2 Specifications

General IconGeneral
BrandOracle
ModelSPARC T7-2
CategoryServer
LanguageEnglish

Related product manuals